Installation, Operation & Maintenance
Instructions
Please leave this instruction booklet with the owner as it contains important
guarantee, maintenance and safety information
Read this manual carefully before commencing installation.
This manual covers the following products:
QT 50 SNH
Pt. No. 49013
QT 50 TNH
Pt. No. 49010
QT 80 SNH
Pt. No. 49014
QT 80 TNH
Pt. No. 49011
QT 120 SNH
Pt. No. 49015
QT 120 TNH
Pt. No. 49012
*2 year as standard extended to 3 years with a Techflange fitted
FOR POSITIVE OR NEGATIVE HEAD APPLICATIONS
Seitenansicht 0
1 2 3 4 5 6 ... 19 20

Inhaltsverzeichnis

Seite 1 - Instructions

Installation, Operation & Maintenance InstructionsPlease leave this instruction booklet with the owner as it contains important guarantee, mainten

Seite 2 - CONTENTS

- 10 -Cont ...4 ELECTRICAL INSTALLATION / EARTHING4.11 Regulations: The electrical installation must be carried out in accordance with the cu

Seite 3

- 11 -Cont ... The wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black. The wire w

Seite 4

- 12 -Cont ...5 COMMISSIONING5.11 System Flushing This pump incorporates push-in connectors and plastic components that must not come into co

Seite 5 - 2 LOCATION - GENERAL

- 13 -Cont ...6.13 No other routine maintenance is required.6.14 Should ever the need arise for the vessel to have its air charge checked or

Seite 6 - 2 LOCATION - SINGLE PUMP

- 14 - e) Replenish air charge if required by injecting air into the vessel via the Schrader valve using a car or bicycle pump, ensuring

Seite 7 - 2 LOCATION - TWIN PUMP

- 15 -Cont ...Techflow reserve the right to amend the specification in line with its policy of continuous development of its products. Note: Fo

Seite 8 - 3 PUMP CONNECTIONS

- 16 -Cont ...7 TECHNICAL SPECIFICATION (Twin Models)Model QT50 TNH QT80 TNH QT120 TNHElectricalPower supplyVolts/phase freqency230/1/50 230/1/50 230/

Seite 9

- 17 -8 TROUBLE SHOOTING GUIDESymptoms Probable Cause Recommended ActionPump will not start. Electrical supply. Check power supply.Check fuse (see fu

Seite 10 - Diagram of

- 18 -Cont ...8.11 Dry Run Protection: This pump is fitted with a PCB that will detect the following fault: Dry running caused by water starvatio

Seite 11 - Cont

- 19 -9. THE TECHFLOW GUARANTEECongratulations on purchasing a Techflow pump. We are confident this pump will provide many years of trouble free serv

Seite 12 - 5 COMMISSIONING

- 2 -Cont ...PRODUCT DESCRIPTIONElectric motor driven single or twin ended centrifugal pump, complete with an automatic control system, consisting of

Seite 13 - 6 MAINTENANCE

Techfl ow Products, Service Department, Greys Road, Henley-on-Thames, Oxfordshire RG9 1RY ENGLAND Tel: +44 (0) 1444 258017, Fax: +44 (0) 1444

Seite 14 - Schrader valve

- 3 -Cont ...CHECKLISTItemDescription QtyItemDescription QtyPump 1 Outlet hose only 2 (1)Inlet hose with isolating valve 2 (1)ABCYour product may vary

Seite 15

- 4 -Cont ...1 READ BEFORE COMMENCING PUMP INSTALLATIONA. Water storage capacity.1.11 The hot and cold water storage capacity must be sufficient to

Seite 16

- 5 -Cont ...2 LOCATION - GENERAL2.11 Access: For emergencies and maintenance the pump must be easily accessible.2.12 Protection: The pump must

Seite 17 - 8 TROUBLE SHOOTING GUIDE

- 6 -Cont ...2 LOCATION - SINGLE PUMP2.25 The cold water supply: The supply must be AIR FREE and have a DEDICATED CONNECTION to the tank whi

Seite 18

- 7 -Cont ...2 LOCATION - TWIN PUMP2.27 Hot water cylinder or storage tank: When a hot water cylinder or storage tank is used, ensure the pipew

Seite 19 - 01444 258017

- 8 -Cont ...3 PUMP CONNECTIONS  Do not use stainless steel, chrome or nickel plated pipe with the flexible hose push-in plumbing connections. 

Seite 20 - Business Development Director

- 9 -Cont ...3. Check in the mouth of the fitting that ‘O’-ring, nylon washer and collet are in position.4. Push pipe firmly into fitting, until